1. Except power cables, all devices shall be wired with Category 6 unshielded twisted pairs. The head video terminal, parking space display screens and car search query terminals adopt TCP/IP protocol. Daisy-chain wiring is applied between the head video terminal and other terminals on the loop.
2. All AC220 high-voltage circuits and low-voltage circuits of the system shall be routed and piped separately. It is strictly forbidden to lay high-voltage and low-voltage cables inside the same conduit. The AC220V power supply of the manager shall be equipped with an earthing wire to ensure reliable equipment earthing; otherwise, circuit interference may cause communication failures.
3. For outdoor wiring, steel conduits are mandatory. Shielded cables shall be selected, and the shielding layer must be reliably earthed.
4. All flexible conductor ends shall be crimped with pre-insulated terminals or tinned.
5. Dedicated wires shall be used for inter-device connections. Wire terminals of each branch shall be properly crimped. Protective earth wires shall be crimped to equipment and shielding nets. Single-point earthing is adopted with an earthing resistance not greater than 1Ω. Equipment enclosures must be reliably earthed.
6. Record all device IP addresses and serial numbers, and compile an IP correspondence table. Video parking space detectors, network controllers, parking space guidance displays and regional guidance screens shall be installed and assigned IP addresses strictly in accordance with system diagrams and layout drawings.